<< ABSOUTE LINEAR ENCODER FOR SIEMENS>>

Model: JAS-10N  

   

JENIX Absolute linear scale, its rail, read head and double sealings are strongly resistant to thermal expansion and

vibration of machines. Aslo it is proper for CNC as it make possible high accurate control.

INTERFACE WITH SIEMENS DRIVE-CLiQ       

  Resolution / Grating glass:    10nm / Single glass with dual track 

 Accuracy: ±5㎛

 Output signal: DRIVE CLiQ

 Power supply: 24V

 Measuring length (mm): 

                   140 240 340 440 540 640 740 840 940 1040 1140 1240 1340 1440 1540 1640 1740 1840 2040 

                   2240 2440 2640 2840 3000 

Maximum cable length: 30m

Maximum speed: 250m/min

Maximum vibration/impact: 20g / 30g

Maximum acceleration: 10g to the measuring direction 

Maximum moving force:   < 5N

Operation temp. / Storage temp.:  0℃ ~ 50℃ / -20℃ ~ 70℃

Relative humidity: 20~80%

Protection grade: IP53(standard),  IP64 with compressed air

 

<<Jenix absolute linear scale with Jenix absolute display counter>>

Model: JSNA / JSSA / JSMA

Jenix ABS linear scale

< Features of absolute linear scale >

▶ Present position is always shown even when a table moved without power.

▶ Low defect rate with no accumulate tolerance

▶ Almost no error due to noise

▶ Redardless of no reading in a point, there is no problem in reading the rest of the area.

▶ Reading is possible even in the faster speed

<How it works>

abs-principle

The absolute sensor detects the light passing through the absolute scale glass and calculates the absolute position through calculation.

The absolute system is fast and accurate and there is no need to return to the origin point.

<Specifications>

Model
JSNA / JSSA / JSMA
Origial Source
Grating glass scale with an abolute track
Resolution
5㎛, 1㎛, 0.5㎛, 0.1㎛
Accuracy
±5㎛
Output signal
SSI
Max./Standard cable length
30m / 3m
Power supply
5V ±5%, 150mA
Max. Speed
250m/min
Max. Vibration
20g
Max. Impact
30g
Max. Acceleration
10g (to measuring direction)
Required moving force
< 5N
Operation temp.
0℃ ~ 50℃
Storage temp.
-20℃ ~ 70℃
Relative humidity
20~80%
Protection grade
IP53(standard)
Measuring length
50mm ~ 3000mm
Dimensions
same as Jenix incremetanl ( JSN, JSS & JSM) linear scale